HIVG 3000KV-600KJ Impulse Voltage Generator
Home > Systems > Impulse Generator > Impulse Generator > >1600KV Range

HIVG 3000KV-600KJ Impulse Voltage Generator

Lead time: 120 days

Mode: HIVG 3000KV-600KJ

Related Standards: 
* IEC 60060-1-2010 High-voltage test techniques - Part 1: General definitions and test requirements
* IEC 60060-2-2010 High-voltage test techniques. Part 2: Measuring systems
* IEC 61083-1-2001 Instruments and software used for measurement in high-voltage impulse tests - Part 1: Requirements for instruments
* IEC 61083-2-1996 Digital recorders for measurements in high-voltage tests - Part 2: Evaluation of software
* ANSI/IEEE 4a-2001 Techniques of High-Voltage Testing
* ANSI/IEEE 376-1975 Measurement of Impulse Strength and Impulse Bandwidth
* ANSI/IEEE 1122-2007 Digit Recorders for Measurements in High-Voltage Impulse Tests
* ASTM D69-D2484 Electrical Insulation ()
* ASTM D2518-Latest Electrical Insulation (
)

Technical Parameters: 
1) Rated Voltage: ±3000kV
2) Rated stage voltage: ±200kV
3) Rated charging voltage: 0~200kV (±100 positive and negative polarity symmetrical charging )
4) Rated energy: 600kJ ±5%                      
5) Each stage impulse capacitor: 2μF/200kV Each stage two capacitor, and 4uF/100kv each. 
6) Overall capacitance: 133.3nF±5%  
7) Stages: 15stages 
8) Stage energy:40kJ±5%  
9) Impulse voltage waveform parameter: 
     a) Standard lightning impulse voltage full-wave: 1.2±30%ms/50±20ms,Amplitude: ±3%,
          oscillation at peak value less than 5% of amplitude
     b) Standard switching impulse wave: 250±20%ms /2500±60%ms
     c) This two impulse voltage waveform parameter and deviation meet the requirement of GB311 and GB16927.
10) Minimum output voltage efficiency
       Standard lightning impulse voltage full-wave≥90% (No test object)
       Standard switching impulse wave≥70% (test object capacitance is 1000pF)
11) Synchronous range: stage voltage is between 10%~100% of rated voltage.
       Positive and negative polarity synchronous range: less than 20%.
12) Synchronous discharge out of control rate <2% (Within the range: 10%~100% of rated voltage )
13)Sparking range: 20%-100%Un
14) Minimum output voltage: ≥10% rated voltage.
15) Charging voltage instability <±1.0%
16) Deviation between charging voltage and reference voltage  <±1.0%
17) Working time: 
       When voltage above than 80% rated voltage, the systems can continuous working each 120s(charging and discharging). 
       When the voltage is below 80% of rated voltage, the system the system can continuous workin(charging and discharging).
18) Under Maximum charging voltage, minimum discharge time not less than 60s.


Principle Diagram: 

  