Download: CTT Serial Cable Test Termination Himalayal.pdf
CTT Serial Cable Test Termination
Description:
The CTT series water-insulated cable test terminations are used to test extruded insulation high-voltage cables.
Cable test terminal is always part of a complete system which consists of HV power source, test object, measuring device, related HV connecting and earthing, water cooling system.
The terminal and water conditioning suitable for the test:
n Partial discharge test
n AC withstand test
n Impulse voltage test
n Tan delta test
General Specification of the Water Terminal
n The terminal suit for Power cable’s delivery test, type test and qualification test.
n The terminal is designed for indoor use.
n The terminal consists of 2 sets terminal tubes and one deionizer water condition unit.
n The terminal suitable for 500kV and below XLPE power cable testing
n Remote control is available.
n Rated voltage of the terminal reaches 800kV.
n Before operating, please make sure every unit are safety earthing.
n Terminal is removable, convenient for testing.
n Deionizer resin can be replaced on-site.
n Water storing case has four tubes for water-in and water-out
n There are emergency button, user can press it when emergency situation to keep safety.
n Electric sensor can supervise the temperature, pressure, flow velocity and water electrical conductivity.
n Sensor supply 4-20mA signal to feed programmable processor, the operation mode will display on the control panel.
ITEM / MODE | CTT-100 | CTT-150 | CTT-300 | CTT-400 | CTT-500 | CTT-600 | CTT-700 | CTT-800 |
Un rated voltage (kV) | 100 r.m.s | 150 r.m.s | 300 r.m.s | 400 r.m.s | 500 r.m.s | 600 r.m.s | 700 r.m.s | 800 r.m.s |
PD level (Un ) (pC) | <1 | <1 | <1 | <2 | <2 | <2 | <2 | <2 |
UI rated impulse voltage (kV) Negative polarity | 450 | 550 | 900 | 1200 | 1300 | 1400 | 1650 | 1800 |
Max. dimension of power cable * (include insulation layer) (mm) | 133 | 133 | 133 | 133 | 133 | 133 | 160 | 180 |
ITEM / MODE | CTT-100 | CTT-150 | CTT-300 | CTT-400 | CTT-500 | CTT-600 | CTT-700 | CTT-800 |
Terminal tilt angle | 30° | 30° | 35° | 35° | 40° | 40° | 45° | 45° |
Dimension (m) L x W | 1.6 x 1.2 | 1.8 x 1.2 | 3.0 x 1.2 | 3.6 x 1.2 | 4.0 x 1.2 | 4.7 x 1.2 | 5.8 x 1.4 | 7.5 x 1.6 |
Cable mounting height (m) | 1.0 | 1.0 | 1.0 | 1.4 | 1.5 | 1.6 | 1.6 | 1.6 |
Terminal mounting height (m) | 1.6 | 1.9 | 2.8 | 3.7 | 4.2 | 5.0 | 5.5 | 6.2 |
Min HV insulation distance (m) | 0.8 | 1.0 | 1.6 | 1.9 | 2.3 | 2.6 | 3.3 | 3.8 |
Terminal weight (two sets together) (kg) | 200 | 250 | 350 | 400 | 450 | 500 | 650 | 800 |
Water Conditioning Unit
ITEM / MODE | CTT-100/CTT-150 CTT-300/CTT-400 | CTT-500/CTT-600 | CTT-700/800 |
Power 50/60Hz | 220V/20A | 220V/20A | 220V/20A |
Max cooling capacitance (kW) | 60 | 120 | 120 |
Water capaitance ( l ) | 500 | 500 | 500 |
Max temperature (℃) | 60 | 60 | 60 |
Max pressure (atm) | 4 | 4 | 4 |
Electric conductivity range (μs /cm) | 0.1—2 | 0.1-2 | 0.1—2 |
Max. ambient temperature (℃) | 35 | 35 | 35 |
Min. ambient Temperature (℃) | 3 | 3 | 3 |
Max. cooling water temperature (℃) | 20 | 20 | 20 |
Min. cooling water flow velocity ( l /min) | 45 | 45 | 45 |
Water pipe head (in) | 3/4” | 3/4” | 3/4” |
Dimension (m) | 1.2x1.4x1.7 | 1.2x1.4x1.7 | 1.2x1.4x1.7 |