DC Hipot
600W-200KV HVDC Hi-pot Test System
Home > Systems > On Site Test System > DC Hipot

600W-200KV HVDC Hi-pot Test System

Lead time: 30 days

1) Output voltage: 200KV
2) Output current: 3mA
3) Output power: 600W
4) Ripple: ≤1%
5) Current precision: Digital display instrument ±(1.5%reading±2character)
6) Voltage precision: Digital display instrument ±(1.5%reading±2character)
7) Over-voltage set value erro: ≤1%
8) Control weight: 6kg;
9) Voltage-multiple weight: 9kg
10) Voltage-multiple Height: 970mm
11) Overload capacity: No-load voltage exceeds10% of rated voltage,10 minutes usage ; Maximum charging current is 1.25 times of rated current 
12) Power supply: Single phase AC 50HZ  220V±10%
13) Working mode: 30 minutes intermittent working ,Max 10 minutes continuous working
14) Ambient conditions: Temperature: -10~40℃, Relative humidity: ≤85% (non-condensing), Altitude: <1500m
15) Capacitance: No limit to test object capacitance 
16) Load capacity: Can use 1.5 times of rated current to charge 
17) Structure: Epoxy FRP insulating cylinder, Air insulation no leakage consideration
18) Features of operation box: Precision 0.75UDC1mA touch button (accuracy≤1.0% ); Most suitable for zinc oxide arrester test; The overvoltage protection uses dial setting; Dual-purpose (vertical and horizontal) international standard case,  easy to use on site.

600W-200KV HVDC Hi-pot Test System 600W-200KV HVDC Hi-pot Test System

600W-200KV HVDC Hi-pot Test System 600W-200KV HVDC Hi-pot Test System

Application:
1) MOA lightening-arrester HVDC hi-pot
2) HVDC hi-pot and leak current measurement for HV electrical equipment, such as transformer, switchgear, and oil-type power cable
3) Leak current measurement for water-cooling DC power generators
4) High-stability DC HV generators with high-precision DC voltage-divider for DC HV standardization
Main Feature: 
1) Co-formed the industry product standards: “ZBF24003-90 Portable DC HV Generator Common Technical Conditions” and
 2) “DLT 848.1-2004 HV Testing Equipment Common Technical Conditions, Part One: DC HV Generator”
3) From the first PWM regulated DC HV generator in China developed in 1992, till today, the DC HV generator series has been sold to 1000 customers with 2857 sales volume till the end of 2013
4) DC HV Generators generate: output voltage 40~1200kV, and output current 2~300mA
5) Highest stability could reach ≤0.05%; Ripple≤0.1%
6) Double-stage voltage-multiplier designed for various test precision requirement
7) Controller and voltage-multiplier can be integrated into a single unit (40kV type) for the convenience of field application
8) ZV-B fully-shielded micro-ammeter: digital LCD covered by conductive glass joint with metal shell, test and shielding cable coaxially led out
9) HV-B Infrared micro-ammeter (optional): Infrared connection, auto test individual and total leak current of double arresters
10) Voltage auto-raise/multi-point test (upgraded Z-VII type): pre-set test voltage, test and record leak current on multi-level voltage
11) Voltage-test open circuit protection, ground protection for the safety of operators
12) Can tolerate HV arcing from large-capacity capacitive test object

  