Mode: HIVG 1500KV-75KJ
Related Standards:
* IEC 60060-1-2010 High-voltage test techniques - Part 1: General definitions and test requirements
* IEC 60060-2-2010 High-voltage test techniques. Part 2: Measuring systems
* IEC 61083-1-2001 Instruments and software used for measurement in high-voltage impulse tests - Part 1: Requirements for instruments
* IEC 61083-2-1996 Digital recorders for measurements in high-voltage tests - Part 2: Evaluation of software
* ANSI/IEEE 4a-2001 Techniques of High-Voltage Testing
* ANSI/IEEE 376-1975 Measurement of Impulse Strength and Impulse Bandwidth
* ANSI/IEEE 1122-2007 Digit Recorders for Measurements in High-Voltage Impulse Tests
* ASTM D69-D2484 Electrical Insulation (Ⅰ)
* ASTM D2518-Latest Electrical Insulation (Ⅱ)
Technical Parameters:
1) Rated voltage: 1500KV
2) Rated capacity: 75KJ
3) Rated stage capacity: 1.0uF (5.0KJ/stage)
4) Rated stage voltage: 100KV
5) Stages: 15
6) Output waveform: (when load capacity is < 3000pF)
±1.2/50us standard lightning impulse full wave, efficiency: >90%;
±250/2500us standard switching impulse full wave, efficiency: >75%
7) Synchronization range: >20%
8) Use Duration:
When <80% rated working voltage, continuous work
When > 80% rated working voltage, working with breaks;
9) Amplitude adjustment erroneous voltage is <1%; the lowest output voltage is not greater than 10% nominal voltage equipment.
10) Synchronization malfunction rate: < 2%
Principle Diagram:
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn