Download: HCL2840 Capacitance Tan Delta Bridge.pdf
Tan Delta Bridge with internal 12kV power supply. There will be two aluminum cases for packing. Above one is for accessories, and below one is for the Tan delta bridge.
Technical Parameters:
Accuracy: Cx±(reading×1%+1pF)
DF tgδ: ±(reading×1%+0.00040)
PF cosφ: ±(reading×1%+0.00040)
Interference: Ratio of interference: current to specimen current is 2:1 ( 200% )
Capacitance Range: Internal HV 3pF~60000pF / 10kV, 60pF~1uF/0.5kV
External HV: 3pF~1.5uF/10kV
Resolution: 0.001pF, 4 digitals
No limit, Resolution: 0.001%
tgδ Range: (C/L/R specimen is automatic recognized)
Input current range: 10μA~5A
Internal HV: 0.5~12kV / 200mA (max)
Accuracy: ±(reading×1%+10V)
Control mode: Rise or fall smoothly
Frequency: 45Hz, 50Hz, 55Hz, 60Hz, 65Hz single frequency
45Hz/55Hz, 55Hz/65Hz, 47.5Hz/52.5Hz dual frequency
External HV: UST: 5A max
GST: 12kV/5A max, 38-72Hz
Test Time: 30s typical may vary in different test mode
Power Supply: 95V~130V,180V~260V,50Hz/60Hz or 1 phase power supply or generator
Display: 128*64 dot matrix
Printer: Thermal printer
Communication Port: RS-232
Operating Temperature: -10℃~50℃
Storage Temperature: -20℃~60℃
Humidity: <90% non-condensing
Dimensions: 46cm(L)*35cm(W)*34cm(H)
Weight:Main unit: 29kg
Cable: 5kg
When test voltage higher than 10kV, tan delta test will need an external gas insulated standard capacitor. The above standard capacitor is 300kV rated voltage and 100pF.
HIMALAYAL provides innovative products that comprise high voltage test equipment, full-set high voltage test instruments, on-site test systems and on-line monitoring systems, and services regarding tests, diagnostics and asset monitoring for clients in power industry. We help to ensure safety and reliability in the power generation, transmission and distribution.
Himalayal Corporation Limited
Tel:+86 21 5059 9069
Email: info@himalayal.com
http://www.himalayal.com
http://www.himalayal.com.cn